S425 pH/ORP Sensor 1″ Threads & Extended Insertion

B2–LS104–020–M30

B5-13202-5T7

B5-11005-07-J

B2-LS103-015-M30

B4-21006-020-M10

B4-35005-020-M10

B4-41001-2T9-M10

B4-21005-015-M10

B4-35004-015-M10

B4-31024-8T9-B06

B4-31004-8T9-B06

B4-32023-5T7-B03

B4-21004-007-M10

B4-35002-005-M10

B4-31003-5T7-B06

B4-53008-020-M10

B4-22005-020-M10

B4-12004-020-M10

B2-LS202-020-M69

B5-11315-020

B5-11007-20-R

B4-82004-8T9-M27

B4-53007-015-M10

B4-22004-015-M10

B4-12003-015-M10

B4-44002-8T9-M27

B4-42002-8T9-M27

B4-72003-8T9-M27

B4-32005-8T9-B03

B4-32004-8T9-B03

B2-LS201-015-M69

B5-11314-015

B5-11006-15-R

B5-13103-8T9

B5-12103-8T9

B5-11355-07J

B4-21002-003-M10

B4-31002-2T3-B06

B4-35001-2T3-M06

B4-53006-007-M10

B4-22003-007-M10

B4-12002-007-M10

B4-32003-5T7-B03

B2-LS102-007-M30

B5-11313-007

B5-11004-07-R

B4-22002-005-M10

B5-11312-005

B5-11003-05-R

B5-13102-5T7

B5-12102-5T7

B5-11321-03J

B5-11002-03-J

B5-13201-003

B4-82002-2T7-G34

B4-82001-2T7-M18

B4-81003-2T9-M12

B4-81002-2T9-M10

B4-81001-2T3-M06

B5-51001-2T9-006

B4-53005-2T5-M10

B4-23001-2T9-M10

B4-22202-015

B4-22001-003-M10

B4-12001-2T5-M10

B4-44001-2T7-M18

B4-42001-2T7-M18

B4-72002-2T7-G34

B4-72001-2T7-M18

B4-32002-2T3-B03

B2-LS101-2T5-M30

B5-11311-2T3

B5-11001-03-R

B5-13101-003

B5-12101-003

  • Built-in temperature compensation
  • Built-in solution ground
  • Custom cable lengths
  • Choice of cable connectors
Categories: ,

Application

In-Line & Submersion

Maximum Flow Rate

10 ft (3 m) per second

Chemical-resistant Wetted Materials

These high quality sensors are constructed of corrosion-resistant wetted materials including Ryton®, Teflon® and glass.

Coaxial Porous Teflon® Reference Junction

The large annular junction resists fouling. Also, the sealed, double-junction reference electrode is highly resistant to poisoning.

Specification

pH Range: 0-14 pH

Redox Range: ± 5000 mV

Temp Range: 0 -105º C

Max Pressure/Temp: 150 psig at 100º C

Reference: Ag-AgCl

Wetted Materials: Ryton, Teflon & Glass

Standard cable length: 3 meters (10 Ft)

Please use this information to build your part number. If you need any assistance please call us on +1-949-829-5555 or 1-800-288-2833.
Part No. 1 2 3 4 5 6 7 8 9 10 11 12
S4 2 5  __ T __  __ __ __ __ __ __ __

1 — 2 Body Style

  • [15] Standard Insertion, No Guard, 1″ NPT

3 — Body Material

  • [R] Ryton
  • [G] Grounded

4 — Liquid Junction

  • [T] Coaxial Teflon®

5 — 6 Measurement Electrode:

  • [33] pH, HT-3 Rugged Dome Bulb
  • [43] pH, HT-4 High pH Bulb (for pH 13 and above)
  • [PB] Redox, Platinum Band

7 — Temperature Compensator:

  • [0] T.C. not required
  • [1] 3K Ohms, used on older models of TBI/Bailey & Uniloc transmitters
  • [9] 301 Ohms for use with older Great Lakes models, such as 60, 70, 90, 570 and 690
  • [D] Pt 100 Ohms for Rosemount (Uniloc) 1054, Beckman SoluComp, TBI/Bailey TB82 & TB84, Foxboro 870 & 874, Yokogawa and many European models
  • [H] Pt 1000 Ohms for Yokogawa, Conducta, Polymetron and many European models

8 — Cable Type:

  • [A] 3 mm Low Noise Coax, for pH without built-in TC, or for Redox
  • [M] 5 mm Low Noise Coax, for pH without built-in TC, or for Redox
  • [E] Jacketed Coax w/ TC leads
  • [N] Jacketed Coax w/ TC and solution ground leads

9 — 10 Cable Length:

  • [10] 10 ft – standard length
  • [XX] Specify length (in feet) if other than standard (see above for price adder per foot)

11 — 12 Sensor Connectors:

  • [BC] BNC only (for use with Redox electrodes or with sensors w/o TC or solution ground)
  • [FB] BNC for pH and Ferrules on all other leads (for use with Terminal Block or Terminal Strip)
  • [FF] All Ferrule connectors (for use with Terminal Block or Terminal Strip)

Sensors