Model 70 DO Transmitter 4-20

B2–LS104–020–M30

B5-13202-5T7

B5-11005-07-J

B2-LS103-015-M30

B4-21006-020-M10

B4-35005-020-M10

B4-41001-2T9-M10

B4-21005-015-M10

B4-35004-015-M10

B4-31024-8T9-B06

B4-31004-8T9-B06

B4-32023-5T7-B03

B4-21004-007-M10

B4-35002-005-M10

B4-31003-5T7-B06

B4-53008-020-M10

B4-22005-020-M10

B4-12004-020-M10

B2-LS202-020-M69

B5-11315-020

B5-11007-20-R

B4-82004-8T9-M27

B4-53007-015-M10

B4-22004-015-M10

B4-12003-015-M10

B4-44002-8T9-M27

B4-42002-8T9-M27

B4-72003-8T9-M27

B4-32005-8T9-B03

B4-32004-8T9-B03

B2-LS201-015-M69

B5-11314-015

B5-11006-15-R

B5-13103-8T9

B5-12103-8T9

B5-11355-07J

B4-21002-003-M10

B4-31002-2T3-B06

B4-35001-2T3-M06

B4-53006-007-M10

B4-22003-007-M10

B4-12002-007-M10

B4-32003-5T7-B03

B2-LS102-007-M30

B5-11313-007

B5-11004-07-R

B4-22002-005-M10

B5-11312-005

B5-11003-05-R

B5-13102-5T7

B5-12102-5T7

B5-11321-03J

B5-11002-03-J

B5-13201-003

B4-82002-2T7-G34

B4-82001-2T7-M18

B4-81003-2T9-M12

B4-81002-2T9-M10

B4-81001-2T3-M06

B5-51001-2T9-006

B4-53005-2T5-M10

B4-23001-2T9-M10

B4-22202-015

B4-22001-003-M10

B4-12001-2T5-M10

B4-44001-2T7-M18

B4-42001-2T7-M18

B4-72002-2T7-G34

B4-72001-2T7-M18

B4-32002-2T3-B03

B2-LS101-2T5-M30

B5-11311-2T3

B5-11001-03-R

B5-13101-003

B5-12101-003

The Model 70 features an easy-to-use, intuitive menu that makes advanced programming and calibration simple. Onscreen full text and phrase prompting does away with cryptic, mnemonic based instrument displays.

Categories: ,

This newest analyzer is available in single or dual sensor input versions. In the case of the dual-sensor version, the enclosure takes up half the space of most other transmitters. The transmitter has two 0/4–20 mA outputs that can be programmed to correspond to the measurement and temperature. Both two- and one-point calibration are available with the Model 70. Easy one-point recalibration, while the instrument is online, makes adjustment after grab sample analysis quick and simple.

Specification

Features & Applications

The Model 70 dual-input analyzer offers single or dual sensor input with an unrestricted choice of dual measurements thus reducing the cost per loop and saving panel space. This multi-parameter instrument offers a wide range of measurement choices. The modular design of the instrument allows signal input boards to be field replaced making configuration changes easy.

Quick Start Programming

Exclusive Quick Start screens appear the first time the Model 70 is powered. The instrument auto-recognizes each measurement board and the display prompts the user to configure each sensor in a few quick steps for immediate deployment.

Menus

Menu screens for calibrating and programming are simple and intuitive. Plain language prompts and help screens guide the user through these procedures.

Dual Sensor Input & Output

The Model 70 accepts single or dual sensor input. Standard 0/4-20 mA current outputs can be programmed to correspond to any measurement or temperature.

Enclosure

The instrument fits standard ½ DIN panel cutouts. The versatile enclosure design supports panel-mount, pipe-mount, and surface/wall-mount installations.

Isolated Inputs

Inputs are isolated from other signal sources and earth ground. This ensures clean signal inputs for single and dual input configuration. For dual input configurations, isolation allows any combination of measurements and signal inputs without cross-talk or signal interference.

Temperature

Most measurements require temperature compensation. The Model 70 will automatically recognize Pt100, Pt1000 or 22k NTC RTDs built into the sensor.

Security Access Codes

Two levels of security access are available. Program one access code for routine calibration and hold of current outputs; program another access code for all menus and functions.

Diagnostics

The analyzer continuously monitors itself and the sensor(s) for problematic conditions. The display flashes Fault and/or Warning when these conditions occur. Information about each condition is quickly accessible by pressing the diagnostic button on the keypad. Help screens are displayed for most fault and warning conditions to guide the user in troubleshooting.

Display

The high-contrast LCD provides live measurement readouts in large display digits and shows up to four additional process variables or diagnostic parameters concurrently. The display is back-lit and the format can be customized to meet user requirements.

Current Outputs

Two 4-20 mA or 0-20 mA current outputs are electrically isolated from other signal sources and earth ground. Outputs are fully scalable and can be programmed to linear or logarithmic modes. Output dampening can be enabled with time constants from 0 to 999 seconds.

Instrument manufactured by
Rosemount Analytical.
MFG Model 1056.

Please use this information to build your part number. If you need any assistance please call us on +1-949-829-5555 or 1-800-288-2833.
Part No. 1 2 3
70 – __ __  __

Standard Configuration Includes:

Analog 0/4-20 mA output, switching AC 85-265VAC power supply, 4 alarm relays.

OPTIONS Complete the reorder P/N by selecting from the following options

1 — Mounting Hardware

  • [A] Panel Mount
  • [B] Pipe/Wall Mount

2 — Measurement Type

  • [PH] Single Input – pH (or Redox; user programmable)
  • [DO] Single Input – Dissolved Oxygen
  • [PH/PH] Dual Input – pH/pH (or Redox; user programmable)
  • [PH/DO] Dual Input – pH/Dissolved Oxygen
  • [DO/DO] Dual Input – Dissolved Oxygen/Dissolved Oxygen

3 — Optional power supply

  • [24] 24 VDC, 4-wire, 4 alarm relays
  • Analog signal
  • Current is proportional and scalable to sensor signal
  • Carries one measured variable in one direction
  • Historical standard for measurement & control

The standard analog communication protocol for over 20 years. The primary variable is transmitted via a 4-20 mA current loop from the field device to the control system. Only one variable can be transmitted per loop. No secondary data is available for the control system, and the field devices can only be calibrated and configured at the device itself in the fermentation or cell culture suite.