C1121K High Pressure In-Line pH Sensor with Integral Housing
B2–LS104–020–M30
B5-13202-5T7
B5-11005-07-J
B2-LS103-015-M30
B4-21006-020-M10
B4-35005-020-M10
B4-41001-2T9-M10
B4-21005-015-M10
B4-35004-015-M10
B4-31024-8T9-B06
B4-31004-8T9-B06
B4-32023-5T7-B03
B4-21004-007-M10
B4-35002-005-M10
B4-31003-5T7-B06
B4-53008-020-M10
B4-22005-020-M10
B4-12004-020-M10
B2-LS202-020-M69
B5-11315-020
B5-11007-20-R
B4-82004-8T9-M27
B4-53007-015-M10
B4-22004-015-M10
B4-12003-015-M10
B4-44002-8T9-M27
B4-42002-8T9-M27
B4-72003-8T9-M27
B4-32005-8T9-B03
B4-32004-8T9-B03
B2-LS201-015-M69
B5-11314-015
B5-11006-15-R
B5-13103-8T9
B5-12103-8T9
B5-11355-07J
B4-21002-003-M10
B4-31002-2T3-B06
B4-35001-2T3-M06
B4-53006-007-M10
B4-22003-007-M10
B4-12002-007-M10
B4-32003-5T7-B03
B2-LS102-007-M30
B5-11313-007
B5-11004-07-R
B4-22002-005-M10
B5-11312-005
B5-11003-05-R
B5-13102-5T7
B5-12102-5T7
B5-11321-03J
B5-11002-03-J
B5-13201-003
B4-82002-2T7-G34
B4-82001-2T7-M18
B4-81003-2T9-M12
B4-81002-2T9-M10
B4-81001-2T3-M06
B5-51001-2T9-006
B4-53005-2T5-M10
B4-23001-2T9-M10
B4-22202-015
B4-22001-003-M10
B4-12001-2T5-M10
B4-44001-2T7-M18
B4-42001-2T7-M18
B4-72002-2T7-G34
B4-72001-2T7-M18
B4-32002-2T3-B03
B2-LS101-2T5-M30
B5-11311-2T3
B5-11001-03-R
B5-13101-003
B5-12101-003
This pH sensor has its own integral housing so that it can be installed into any 1/2″ NPT pipe fitting. No separate housing is needed because the electrode and the threaded housing are built into one unit.
Sealed Ag/AgCl reference with coaxial ceramic junction
Single junction reference design (1X)
3 meter (10 ft) cable, BNC Connector
Additional Notes:
Combination electrodes are designed such that both the pH measuring electrode and the reference electrode are built into one probe. Ease of handling and small size make this a very popular design.
pH sensor is threaded to fit directly into the pipe.
Part No.: C1121K-32A-A10BC
Standard 1/2" Tee joint
Specification
pH Range: 0–13 pH
Redox Range: ± 5000 mV
Temp Range: -5º to 105ºC
Max Pressure/Temp: 100 psig at 100ºC, 150 psig at 25ºC
Reference System: Ag/AgCl
Reference Electrolyte: 3.8M KCl, Saturated with AgCl
Glass Membrane Type: HT-3, Low Sodium Ion error
Membrane Resistance: 100 Megohms
Zero Potential: 7.0 pH
Wetted Materials: Glass and Ceramic
Cap: 1/2" NPT
Connector: BNC Plug
Standard cable length: 3 meter (10 ft) low noise cable
Broadley-James pH Electrodes for Agricultural Applications are:
Economical
Broadley-James pH electrodes are a cost-effective component of hydroponics systems. Whether pH is measured as part of an in-line nutrient dosing unit or the pH of the hydroponics bays is tested manually, the affordable pH electrode is a vital part of a nutrient management system. Broadley-James pH electrodes can be used with nearly all systems that are available on the market. The company has more than two decades of experience in horticultural pH measurement and control applications.
Long Lasting
Broadley-James pH electrodes are durable and designed for maximum performance. With proper care and maintenance, Broadley-James pH electrodes will continually help maintain optimal growing conditions in hydroponics bays. Accurate measurement of pH is critical to provide precise pH control and dosing of the nutrients to achieve the highest yields. Easy to maintain and exchange when needed, these pH sensors can be quickly replaced to minimize loss in production time.
Compatible
Broadley-James is the most complete source of replacement pH electrodes for hydroponics, and has an extensive selection of pH sensors to fit the most widely used systems. Whether using a conventional housing, the newer twist-lock housing, or measuring pH manually, Broadley-James has pH sensors that are compatible with all brands of electronics and controllers.
If you do not see your style of pH sensor pictured here, call a Broadley James representative today for further assistance.
New Twist-Lock Housing with Sensor installed
Conventional Threaded Housing with Sensor installed
One of the most common problems that growers encounter with pH sensors in agricultural applications is corrosion of the connectors due to moisture. If the connectors get wet, the output of the sensor will be shorted making calibration of the pH sensor impossible. To prevent the sensor from malfunctioning, it is very important to keep the connectors dry in a water-culture system.
Note: All sensors come standard with a 10 foot (3 meter) low noise coaxial cable and either a BNC Plug or a crimped Ferrule connector.
To order a sensor with the fully ferruled connector, simply change BC to FF at the end of any sensor part number.