NEW
Downstream

B2–LS104–020–M30

B5-13202-5T7

B5-11005-07-J

B2-LS103-015-M30

B4-21006-020-M10

B4-35005-020-M10

B4-41001-2T9-M10

B4-21005-015-M10

B4-35004-015-M10

B4-31024-8T9-B06

B4-31004-8T9-B06

B4-32023-5T7-B03

B4-21004-007-M10

B4-35002-005-M10

B4-31003-5T7-B06

B4-53008-020-M10

B4-22005-020-M10

B4-12004-020-M10

B2-LS202-020-M69

B5-11315-020

B5-11007-20-R

B4-82004-8T9-M27

B4-53007-015-M10

B4-22004-015-M10

B4-12003-015-M10

B4-44002-8T9-M27

B4-42002-8T9-M27

B4-72003-8T9-M27

B4-32005-8T9-B03

B4-32004-8T9-B03

B2-LS201-015-M69

B5-11314-015

B5-11006-15-R

B5-13103-8T9

B5-12103-8T9

B5-11355-07J

B4-21002-003-M10

B4-31002-2T3-B06

B4-35001-2T3-M06

B4-53006-007-M10

B4-22003-007-M10

B4-12002-007-M10

B4-32003-5T7-B03

B2-LS102-007-M30

B5-11313-007

B5-11004-07-R

B4-22002-005-M10

B5-11312-005

B5-11003-05-R

B5-13102-5T7

B5-12102-5T7

B5-11321-03J

B5-11002-03-J

B5-13201-003

B4-82002-2T7-G34

B4-82001-2T7-M18

B4-81003-2T9-M12

B4-81002-2T9-M10

B4-81001-2T3-M06

B5-51001-2T9-006

B4-53005-2T5-M10

B4-23001-2T9-M10

B4-22202-015

B4-22001-003-M10

B4-12001-2T5-M10

B4-44001-2T7-M18

B4-42001-2T7-M18

B4-72002-2T7-G34

B4-72001-2T7-M18

B4-32002-2T3-B03

B2-LS101-2T5-M30

B5-11311-2T3

B5-11001-03-R

B5-13101-003

B5-12101-003

SingleSense®

D1430-120-V8

Hybrid® OxyProbe® DO Sensor
for SU100 Series BPC Gas Wells

The D1430 is an amperometric dissolved oxygen (DO) sensor designed for use with SU100 series BPC gas wells. The sensor performs continuous DO measurement behind the rugged, sterile, steel-mesh reinforced gas permeable membrane barrier of the gas well.

Category:
Sensor works behind sterile barrier of any SU100 series BPC gas well; does not need to be sterilized
Avoiding the need to insert the sensor directly into the BPC reduces the risk of BPC media contamination
The D1430 can be removed mid-run for calibration check if needed

The D1430 Hybrid® OxyProbe® is an amperometric dissolved oxygen (DO) sensor designed for use with SU100 series BPC gas well. The sensor performs continuous measurement behind the rugged, sterile, steel-mesh reinforced membrane barrier of the gas well, eliminating the need to heat sterilize the sensor. The sensor has no wetted materials as the gas well prevents the sensor from direct contact with the BPC media.

The D1430 nanoamp output is compatible with nanoamp input DO transmitters and similar instrumentation. The sensor output can be converted to Modbus RTU with a SmartSync® signal conditioner.

The D1430 threads directly into any SU100 series BPC gas well using the sensor’s Pg13.5 threaded fitting. Hand tightened. No tools needed.

Sensor Specifications

Measurement Range 0–500 nAmps [0–300% SAT]
Operational Temp. Range 5°–50° C [41°–122° F]
Pressure Range 0–3750 mmHg [0–72 psig]
Response Time: T98 < 15 seconds at 37° C; N2 to AIR
T98 < 15 seconds at 37° C; AIR to N2
Accuracy Within 1% full scale (% SAT)
Sterilization Temperature Not heat sterilizable. For use only with SU100 series single-use BPC gas wells.
Insertion Length 120 mm
Sensor/BPC Gas Well Interface Pg13.5 Threads
Sensor Connector 8-pin Variopin
Sensor Output
  • Analog: nAmps
  • Metadata: Digital: SensorTalk™
Power Supply Not applicable
Storage Temperature 5°–35° C [41°–95° F]
Shelf Life 60 months

 

How to Purchase

Please review the product purchasing sheet for product specifications and purchasing information.

Contact our sales team for more information.

Technical Sales